This test case has been proposed by Annabelle Le-Hyaric and Michel Fouquembergh formerly at AIRBUS.

We consider a 2D model representative of the neighboring of an electronic component submitted to a cooling air flow. It is described by four geometrical domains in R2 named Ωi,i=1,2,3,4, see figure. We suppose the velocity v is known in each domain --- for instance in Ω4 it is the solution of previous Navier-Stokes computations. --- The temperature T of the domain Ω=4i=1Ωi is then solution of heat transfer equation :

ρCi(Tt+vT)(kiT)=Qi,i=1,2,3,4

where t is the time and in each sub-domain Ωi, ρCi is the volumic thermal capacity, ki is the thermal conductivity. k1 and k2 are parameters of the model.

ICs dissipate heat, so the volumic heat dissipated Q1 and Q2 are also parameters of the model, while Q3=Q4=0.

eads geometry

One should notice that the convection term in heat transfer equation may lead to spatial oscillations which can be overcome by Petrov-Galerkin type or continuous interior penalty stabilization techniques.

Integrated circuits (ICs) (domains Ω1 and Ω2 ) are respectively soldered on PCB at x1=(ePcb,h1) and x2=(ePcb,h2). They are considered as rectangles with width eIC and height hIC. The printed circuit board (PCB) is a rectangle Ω3 of width ePCB and height hPCB. The air(Air) is flowing along the PCB in domain Ω4. Speed in the air channel Ω4 is supposed to have a parabolic profile function of x coordinate. Its expression is simplified as follows (notice that v is normally solution of Navier-Stokes equations; the resulting temperature and velocity fields should be quite different from that simplified model), we have for all 0yhPCB

ePcb+eIcxePcb+ea,v=V(x(ePcb+eIc))(x(ePcb+ea))yePcbxePcb+eIc,v=0

where V is a parameter of the model.

The medium velocity vi=0,i=1,2,3 in the solid domains Ωi,i=1,2,3.

1. Boundary conditions

We set

  • on Γ1Γ3, a zero flux (Neumann-like) condition

ki Tni = 0;
  • on Γ2, a heat transfer (Robin-like) condition

k4 Tn4 = h(TT0);

where h is a parameter of the model

  • on Γ4 the temperature is set (Dirichlet condition)

T =T0;
  • on other internal boundaries, the coontinuity of the heat flux and temperature, on Γij=ΩiΩj

Ti=Tjki Tni=kj Tnj.

2. Initial condition

At t=0s, we set T=T0.

3. Outputs

The output is the mean temperature s1(μ) of the hottest IC

s1(μ)=1eIChICΩ2T

4. Parameters

The table displays the various fixed and variables parameters of this test-case.

Table 1. Table of model order reduction parameters

Name

Description

Range

Units

k1

thermal conductivity

[1,3]

Wm1K1

k2

thermal conductivity

[1,3]

Wm1K1

h

transfer coefficient

[0.1,5]

Wm2K1

Q1

heat source

[104,106]

Wm3

Q1

heat source

[104,106]

Wm3

V

Inflow rate

[1,30]

m2s1

Table 2. Table of fixed parameters

Name

Description

Nominal Value

Units

t

time

[0,500]

s

T0

initial temperature

300

K

IC Parameters

ρCIC

heat capacity

1.4106

Jm3K1

eIC

thickness

2103

m

hIC=LIC

height

2102

m

h1

height

2102

m

h2

height

7102

m

PCB Parameters

k3=kPcb

thermal conductivity

0.2

Wm1K1

ρC3

heat capacity

2106

Jm3K1

ePcb

thickness

2103

m

hPcb

height

13102

m

Air Parameters

T0

Inflow temperature

300

K

k4

thermal conductivity

3102

Wm1K1

ρC4

heat capacity

1100

Jm3K1

ea

thickness

4103